Products > Cartridge > High density cartridge heaters > Standard CCHC
Dimension specifications
Standard voltage = 230 V (220/240 V)
Standard leads length = 250 mm (flexible leadwires)
NC = Unheated Length
L = Length of the steel sheath
|
|
Standard in metrics
Nominal diameter |
6.5 |
8 |
10 |
12.5 |
16 |
20 |
Tolerances |
-0.03 -0.05 |
-0.04 -0.06 |
-0.04 -0.07 |
-0.05 -0.08 |
-0.05 -0.08 |
-0.06
-0.1 |
Ø Real maxi mini |
6.47 6.45 |
7.96 7.94 |
9.96 9.93 |
12.45 12.42 |
15.95
15.92 |
19.94
19.9 |
Minimum Length
maxi standard |
32
160 |
32
160 |
32
200 |
40
300 |
40
300 |
40 300 |
maxi on request |
1000 |
1000 |
1350 |
1350 |
2000 |
2000 |
Standard in inches
Nominal diameter |
1/4'' 6.35 |
3/8'' 9.52 |
1/2'' 12.7 |
5/8'' 15.87 |
3/4'' 19.05 |
1’’
25.4
|
Tolerances |
-0.03 -0.05 |
-0.04 -0.07 |
-0.05 -0.08 |
-0.05 -0.08 |
-0.06 -0.1 |
-0.06
-0.16 |
Real maxi mini |
6.32 6.3 |
9.48 9.45 |
12.65 12.62 |
15.82 15.79 |
18.99 18.95 |
25.34
25.24 |
Length mini |
1''1/4
31.75 |
1''1/4
31.75 |
1''1/2
38.1 |
2''
50.8 |
2''1/2
63.5 |
2’’1/2
63.5 |
Maxi standard |
6''
152.4 |
8''
203.2 |
12''
304.8 |
12''
304.8 |
12''
304.8 |
|
Maxi on request |
36’’
914 |
36’’
914 |
52’’
1320 |
52’’
1320 |
78’’
1981 |
78’’
1981 |
Tolerances on the length : Length of less than 100 mm : + or - 2mm Length of more than 100 mm : + or - 2% of the total length Tolerance on the camber : 0.15% of the length
Electric characteristics
Nickel leads with silicone fiberglass oversleeve, insulate the wires to temperatures of 320°C
wire section in mm² |
0.22² |
0.5² |
0.75² |
1² |
1.5² |
2² |
2.5² |
4² |
Intensity in A |
0 to 1.74 |
0 to 2.6 |
0 to 4.5 |
4.51 to 5.5 |
5.51 to 7 |
7.01 to 8.7 |
8.71 to 10.86 |
10.87 to 15 |
Diameter |
1/4'' 6.5 |
8 |
3/8'' 10 |
1/2'' 12.5 |
5/8'' 16 |
3/4'' 20 |
1’’ |
Voltage maxi (V) |
240 |
240 |
240 |
400 |
480 |
480 |
480 |
Amps maxi (A)
Standard |
2.6 |
4.5 |
5.5 |
7 |
8.7 |
10.8 |
|
Amps maxi (A)
Outside lead connection without head
(Option 29) |
4.5 |
4.5 |
7 |
11 |
14 |
18 |
23 |
MINIMUM WATTAGE AT 230 VOLTS FOR A LENGTH OF :
Diameter |
1/4'' 6.5 |
8 |
3/8'' 10 |
1/2'' 12.5 |
5/8'' 16 |
3/4'' 20 |
1" |
32mm or 1 1/4'' |
100 |
100 |
75 |
|
|
|
|
40mm or 1 1/2'' |
60 |
55 |
45 |
30 |
25 |
|
|
50 mm or 2'' |
40 |
35 |
30 |
20 |
15 |
|
|
60 mm or 2 1/2'' |
30 |
25 |
25 |
15 |
10 |
10 |
10 |
MAXIMUM WATTAGE FOR A VOLTAGE OF :
Diameter |
1/4'' 6.5 |
8 |
3/8'' 10 |
1/2'' 12.5 |
5/8'' 16 |
3/4'' 20 |
1’’ |
12 V |
31 |
54 |
66 |
104 |
129 |
129 |
|
24 V |
62 |
108 |
132 |
208 |
259 |
259 |
|
48 V |
124 |
216 |
264 |
416 |
518 |
518 |
|
110 V |
286 |
495 |
605 |
957 |
1188 |
1188 |
|
230 V
(standard) |
598 |
1035 |
1265 |
2001 |
2484 |
2484 |
|
230 V
Outside lead connection without head
(Option 29) |
1035 |
1035 |
1610 |
2530 |
3220 |
4140 |
5290 |
230V tri
Outside lead connection without head
(Option 29) |
|
|
|
|
|
7170 |
9200 |
400 V
(standard) |
|
|
|
3480 |
4104 |
4104 |
9200 |
400 V tri
Outside lead connection without head
(Option 29) |
|
|
|
|
|
12420 |
15870 |
Electric tolerances Wattage (Watt) and Europeen norm EN 60335 : +5% -10% Resistance (ohm) : +10% -5%
The ohmic resistance of the cartridge heater is linked to the temperature.
On a cold CCHC it will be reduced by 5 % to the nominal value used for the following calculation (under heat). All wattage figures are calculated when operating. Leakage current are under 0,5 mA / KW or 0,5mA according to the International Standard.
Tolerances on quantities :
CCHC on stock : none.
CCHC special : according to the chart. |
Pieces ordered |
Variation |
1 à 5 |
exact quantity |
6 à 9 |
+1 -0 |
10 à 19 |
+2 -0 |
20 à 49 |
+3 -0 |
50 à 99 |
+4 -0 |
100 and more |
+5% -0 |
|